ET372 InstrumentationMeasurementandLab(For Jack.Jones only)

  • Instrumentation Measurement & Lab

    Digital Signal Conditioning Lab

    1. For the comparator below, complete the design so that the threshold voltage is 1.25V which means that if the input is below 1.25V, the output will be HIGH and if its greater, it will be low. Once the resistance values are found, use Multisim to validate the design by applying a sine wave of 3Vpp into Vin and plot the results.

      figure 1

    2. Using the 8 bit Digital-to-Analog (VDAC) in Multisim, design the part with a 12V reference. Next apply the following inputs in the table below and both calculate and measure the output voltage. What is the resolution of the DAC? Show your circuit and results in Multisim.
    Digital Inputs Calculated Analog Output Voltage Measured Analog Output Voltage
    7 6 5 4 3 2 1 0
    0 0 0 0 0 0 0 1    
    0 0 0 0 1 0 0 1    
    0 0 0 1 0 0 0 0    
    0 0 0 1 1 1 1 1    
    0 1 0 1 0 1 0 1    
    1 0 0 0 0 0 0 0    
    1 1 1 1 1 1 1 1    


    assignment image

    copyright

     

  • Instrumentation Measurement & Lab

    Thermal Sensors Lab

    1. In a processing plant, a chemical tower has a liquid which is vaporized. However, if the vapor in the tower reaches 150°C, an alarm needs to be generated so that safe shutdown of that system of the plant may be initiated. An RTD will be used to measure the temperature of the vapor. The RTD will generally operate between 80° to 175°C and has a resistance of 220Ω at 20°C. The fractional change in resistance per 1°C is 0.0040. The dissipation constant is 25mW/°C. Design a circuit to activate an LED alarm when the temperature reaches 150 °C. The error should not exceed +/-1°C. Use a single supply voltage.
      1. Draw a block diagram for your design. Explain the function of each block and why it is needed.
      2. Design the circuit showing all calculations. Choose standard resistor values, and specify the tolerances. Provide a drawing of your circuit with all resistor values and tolerances and parts. You may do this by creating it in Multisim and then drawing the values on as appropriate.
      3. Construct the circuit in Multisim using the resistor values you chose and tolerances. Do a screenshot showing how you have set up the tolerances for the resistors. For the RTD, you may use a potentiometer or variable resistor for which you can change the resistance for different temperatures. If you have a bridge circuit with a potentiometer for nulling, explain how you decide what resistance to use for the null.
      4. Create a table of temperature, RTD resistance, RTD resistance adjusted for self-heating, LED Status. Test your circuit, and use the table to display your results. Find the precise resistance and temperature at which the LED turns on. Provide several screenshots showing the resistance which reflects the RTD resistance value used in the circuit and the LED alarm. Which RTD resistance do you use in the circuit for testing?
      5. Put together all of the above in a well-written report including introduction, requirements, block diagram, design calculations, final design (including any potentiometer settings), testing (including which RTD resistance is used in the circuit for testing), and analysis of results. Be sure to provide a summary at the end, noting at which temperature the alarm was activated, if this was as designed, and what accounts for differences. Please note any problems you encountered.
      6. Entitle your report as EE372W3LYourGID.docx (or other word processing document). Save your Multisim file as EE372W3LYourGID.ms. Submit both documents.

    Laboratory Rubric

    Block diagram and functionality 10
    Correct RTD calculations 15
    Circuit design calculations 15
    Reasonable choices of resistors, tolerances, other design parameters 5
    Constructs circuit in Multisim, uses tolerances, nulls circuit correctly as applicable 10
    Testing technique using table – complete, based on proper resistance 15
    Operates as intended 10
    Summary discussion of performance against requirements and what to reevaluate or changes to make if requirements not met 10
    Report – complete with screenshots, calculations, well-written, professional 10
    Total 100

 

WHAT OUR CURRENT CUSTOMERS SAY

  • Google
  • Sitejabber
  • Trustpilot
Zahraa S
Zahraa S
Absolutely spot on. I have had the best experience with Elite Academic Research and all my work have scored highly. Thank you for your professionalism and using expert writers with vast and outstanding knowledge in their fields. I highly recommend any day and time.
Stuart L
Stuart L
Thanks for keeping me sane for getting everything out of the way, I’ve been stuck working more than full time and balancing the rest but I’m glad you’ve been ensuring my school work is taken care of. I'll recommend Elite Academic Research to anyone who seeks quality academic help, thank you so much!
Mindi D
Mindi D
Brilliant writers and awesome support team. You can tell by the depth of research and the quality of work delivered that the writers care deeply about delivering that perfect grade.
Samuel Y
Samuel Y
I really appreciate the work all your amazing writers do to ensure that my papers are always delivered on time and always of the highest quality. I was at a crossroads last semester and I almost dropped out of school because of the many issues that were bombarding but I am glad a friend referred me to you guys. You came up big for me and continue to do so. I just wish I knew about your services earlier.
Cindy L
Cindy L
You can't fault the paper quality and speed of delivery. I have been using these guys for the past 3 years and I not even once have they ever failed me. They deliver properly researched papers way ahead of time. Each time I think I have had the best their professional writers surprise me with even better quality work. Elite Academic Research is a true Gem among essay writing companies.
Got an A and plagiarism percent was less than 10%! Thanks!

ORDER NOW


Consider Your Assignments Done

“All my friends and I are getting help from eliteacademicresearch. It’s every college student’s best kept secret!”

Jermaine Byrant
BSN

“I was apprehensive at first. But I must say it was a great experience and well worth the price. I got an A!”

Nicole Johnson
Finance & Economics

Our Top Experts

See Why Our Clients Hire Us Again And Again!


OVER

10.3k
Reviews

RATING
4.89/5
Average

YEARS
13
Mastery

Success Guarantee

When you order form the best, some of your greatest problems as a student are solved!

Reliable

Professional

Affordable

Quick

Using this writing service is legal and is not prohibited by any law, university or college policies. Services of Elite Academic Research are provided for research and study purposes only with the intent to help students improve their writing and academic experience. We do not condone or encourage cheating, academic dishonesty, or any form of plagiarism. Our original, plagiarism-free, zero-AI expert samples should only be used as references. It is your responsibility to cite any outside sources appropriately. This service will be useful for students looking for quick, reliable, and efficient online class-help on a variety of topics.