Fill in Order Details

  • Submit paper details for free using our simple order form

Make Payment Securely

  • Add funds to your account. There are no upfront payments. The writer will only be paid once you have approved your paper

Writing Process

  • The best qualified expert writer is assigned to work on your order
  • Your paper is written to standard and delivered as per your instructions

Download your paper

  • Download the completed paper from your online account or your email
  • You can request a plagiarism and quality report along with your paper

Comparison between Manual Device and Automated Blood Pressure Cuff

Comparison between Manual Device and Automated Blood Pressure Cuff

Author’s name

Institutional Affiliation

Table of Contents

TOC o “1-3” h z u Comparison between Manual Device and Automated Blood Pressure Cuff PAGEREF _Toc317675784 h 3Introduction PAGEREF _Toc317675785 h 3Review of the Articles PAGEREF _Toc317675786 h 3Discussion PAGEREF _Toc317675787 h 4Conclusion PAGEREF _Toc317675788 h 5References PAGEREF _Toc317675789 h 6

Comparison between Manual Device and Automated Blood Pressure CuffIntroductionThis paper posits to provide a comparison between manual device and automated blood pressure cuff. It will base the comparison on two topical journal articles in this regard. Debates concerning patient populations, clinical trials, as well as statistical analyses may appear to be distant and hollow when observing an anxious patient inside an examination room. At such a moment, what matters are the patient’s best interests. Yet clinically pertinent data, and more significantly, careful discussion of that information provides the solution. Professional clinicians often require the former so as to successfully deliver the latter (Landgraf et al., 2010). In this regard, two comparable journal articles were in recent times published arriving at arrived two different conclusions. The first journal is “Comparison of Automated Oscillometric Versus Auscultatory Blood Pressure Measurement”, authored Johanna Landgraf, Stanley Wishner, and Robert Kloner. The American Journal of Cardiology published this journal. The other article is “Why Automated Office Blood Pressure Should Now Replace the Mercury Sphygmomanometer”, authored by Martin G. Myers. This article is available in the Journal of Clinical Hypertension. 

Review of the ArticlesIn the first journal, the authors introduce concerns regarding the utilization of automated oscillometric BP devices. The article reports significant dissimilarity observed in blood pressure readings taken concurrently by use of the auscultatory/mercury procedure as well as the automated oscillometric procedure. The authors report that manual auscultatory outcomes were characteristically higher than the ones utilizing automated oscillometric devices, predominantly in aged patients. The mean inconsistency between techniques was reported as approximately 2 mm Hg. The major concern in the article is the likelihood for a number of hypertensive patients to undergo under treatment as a result (Landgraf et al., 2010).

In the second article, Myers asserts that, the mercury sphygmomanometer has become a hindrance to the provision of optimum care towards the patient with hypertension in regular clinical practice. The author’s argument is based on the multitude of extraneous factors connected with manual blood pressure measurement in the real-life world, which lead to blood pressure readings of erratic accuracy and quality. Myers alleges that automated oscillometric devices that have been autonomously validated for precision would help eliminate such variability (Myers, 2010).

DiscussionTechnical observations concerning the first article assert that the discrepancies between automated and manual techniques are significant. It may be inaccurate to allege that an observer mean SYS of 133 +/- 20 mmHg is considerably larger than the device mean SYS of 131 +/- 18 mmHg. On the contrary, these values are reasonably comparable in the majority of clinical settings. This is the case especially when considering that the majority of auscultatory BPs performed by medical staff depicts faster deflation rates than alleged by the study. Additionally, since the study utilized the same cardiologist for each of the manual readings, it would be probable that an observer-to-observer assessment would depict similar differences.

The majority of clinical offices depend on automated oscillometric devices in measuring blood pressure, but the precision of this technique as opposed to, auscultatory determination utilizing a mercury manometer is contentious. According to Landgraf et al. (2010) to determine the precision of readings from automated oscillometric, blood pressure was computed from the same cuff and site, in 337 successive patients seen in a regular cardiology office, utilizing a simultaneous link to an automated oscillometric as well as, a mercury manometer procedure. The mean systolic BP (133 ± 20 mm Hg) as well as diastolic BP (72 ± 11 mm Hg) were considerably greater in using the mercury manometer than with the automated oscillometric procedure (systolic 131 ± 18 and diastolic 70 ± 12 mm Hg, p <0.0001). Divergence, roughly at all times lower oscillometric as well as greater mercury manometer in systolic blood pressure were observed in 22% of all patients. Divergence in diastolic blood pressure was observed in 20% of all patients. The mean of the divergence between the two procedures was 1.95 ± 5 mm Hg (range 1 to 26) for systolic blood pressure and 1.3 ± 4 mm Hg (range 1 to 25) for diastolic blood pressure. The divergence was larger in patients above 65 years of age.

ConclusionThe mercury manometer procedure led to consistently larger blood pressure values than in oscillometric devices. These outcomes bear imperative clinical implications, together with the theory that patients whose blood pressure seems to be under control in utilizing the oscillometric technique may not be in their goal BP and may have under gone under treatment.

ReferencesLandgraf, J., Stanley, W., & Robert, K. (2010). Comparison of Automated Oscillometric versus Auscultatory Blood Pressure Measurement. American Journal of Cardiology, 106, (3). 386-388.

Myers, M. (2010). Why Automated Office Blood Pressure Should Now Replace the Mercury Sphygmomanometer. The Journal of Clinical Hypertension, 12, (7), 1.

WHAT OUR CURRENT CUSTOMERS SAY

  • Google
  • Sitejabber
  • Trustpilot
Zahraa S
Zahraa S
Absolutely spot on. I have had the best experience with Elite Academic Research and all my work have scored highly. Thank you for your professionalism and using expert writers with vast and outstanding knowledge in their fields. I highly recommend any day and time.
Stuart L
Stuart L
Thanks for keeping me sane for getting everything out of the way, I’ve been stuck working more than full time and balancing the rest but I’m glad you’ve been ensuring my school work is taken care of. I'll recommend Elite Academic Research to anyone who seeks quality academic help, thank you so much!
Mindi D
Mindi D
Brilliant writers and awesome support team. You can tell by the depth of research and the quality of work delivered that the writers care deeply about delivering that perfect grade.
Samuel Y
Samuel Y
I really appreciate the work all your amazing writers do to ensure that my papers are always delivered on time and always of the highest quality. I was at a crossroads last semester and I almost dropped out of school because of the many issues that were bombarding but I am glad a friend referred me to you guys. You came up big for me and continue to do so. I just wish I knew about your services earlier.
Cindy L
Cindy L
You can't fault the paper quality and speed of delivery. I have been using these guys for the past 3 years and I not even once have they ever failed me. They deliver properly researched papers way ahead of time. Each time I think I have had the best their professional writers surprise me with even better quality work. Elite Academic Research is a true Gem among essay writing companies.
Got an A and plagiarism percent was less than 10%! Thanks!

ORDER NOW

CategoriesUncategorized

Consider Your Assignments Done

“All my friends and I are getting help from eliteacademicresearch. It’s every college student’s best kept secret!”

Jermaine Byrant
BSN

“I was apprehensive at first. But I must say it was a great experience and well worth the price. I got an A!”

Nicole Johnson
Finance & Economics

Our Top Experts

See Why Our Clients Hire Us Again And Again!


OVER

10.3k
Reviews

RATING
4.89/5
Average

YEARS
13
Mastery

Success Guarantee

When you order form the best, some of your greatest problems as a student are solved!

Reliable

Professional

Affordable

Quick

Using this writing service is legal and is not prohibited by any law, university or college policies. Services of Elite Academic Research are provided for research and study purposes only with the intent to help students improve their writing and academic experience. We do not condone or encourage cheating, academic dishonesty, or any form of plagiarism. Our original, plagiarism-free, zero-AI expert samples should only be used as references. It is your responsibility to cite any outside sources appropriately. This service will be useful for students looking for quick, reliable, and efficient online class-help on a variety of topics.